ECOsilence

What

ECOsilence is a flat, resilient underlayment used directly under most floor finishes. It yields exceptional results even under hard surface flooring and over concrete and wood joist construction. ECOsilence offers many performance benefits. Installers can thin-set ceramic and porcelain tile directly to it per ASTM C627, it's compatible with most floor finishes, and can be installed quickly.
Compared to other underlayments, ECOsilence performs better. Five millimeter (mm) ECOsilence stands up better than 12 mm cork per ASTM E2179. In addition to these benefits, ECOsilence is available in 48-inch wide rolls and a variety of thicknesses.

Why

  • Compatible with most floor finishes
  • Made from recycled rubber
  • Exceed IIC requirements
  • Adheres to IAQ standards and building costs
  • Lifetime warranty
  • Maintain a low profile             

Underlayments

Available in three options, the ECOsilence collection brings the simplicity and performance of the field's most trusted sound control underlayment to architects and designers.

ECOsilence 2 Order Sample
Standard:
2.0MM
IIC Rating: Up to 19 (dB)
ECOsilence 5 Order Sample
Standard:
5.0MM
IIC Rating: Up to 23 (dB)
ECOsilence 10 Order Sample
Standard:
10.0MM
IIC Rating: Up to 26 (dB)

Accessories

Perimeter Isolation Strips Order Sample
Standard:
6MM

Perimeter isolation strips consist of expanded, closed cell, plank, polyethylene foam that minimizes lateral sound transmission.

Wood Frame Tests

Finish
Underlayment(s)
Ceiling
Gypsum
ΔIIC
STC*
Details
Tests
PDF
Tile
5mm
Yes
1"
50
60
Weyerhaeuser 9.5" TJI with Flak Jacket Fire Protection
NGC 7013055, 5013034
Woods
5mm
Yes
1"
50
58
Weyerhaeuser 9.5" TJI with Flak Jacket Fire Protection
NGC 7013056, 5013035
Finish
Underlayment(s)
Ceiling
Gypsum
ΔIIC
STC*
Details
Tests
PDF
LVT
2mm
Yes
1"
50
63
2mm beneath gypsum concrete
ATI C8706 05-113-11-R0
LVT
2mm, 2mm
Yes
1"
52
63
2mm above and beneath gypsum concrete
ATI C8706 02-113-11-R0
LVT
5mm, 2mm
Yes
1"
53
63
5mm above, 2mm beneath gypsum concrete
ATI C8706 03-113-11-R0
LVT
10mm, 2mm*
Yes
1"
53
63
10mm above, 2mm beneath gypsum concrete
ATI C8706 04-113-11-R1
Laminate
2mm
Yes
1"
53
63
2mm beneath gypsum concrete
ATI C7016 01-113-11-R0
Ceramic Tile
5mm
Yes
None
52
63
5mm beneath 8mm cement board
ATI D0875.02-113-11-R0

* Neither LVT nor tile over 10mm ECOsilence are considered recommended systems, but this test report is provided as an indication of acoustic performance.

Finish
Underlayment(s)
Ceiling
Gypsum
ΔIIC
STC*
Details
Tests
PDF
Tile
5mm
Yes
No
56
NGC 7002038
Tile
10mm*
Yes
No
59
NGC 7002041
Wood
5mm
Yes
1"
51
NGC 7002053

* Neither LVT nor tile over 10mm ECOsilence are considered recommended systems, but this test report is provided as an indication of acoustic performance.

Concrete Slab Tests

Finish
Underlayment(s)
Ceiling
Gypsum
ΔIIC
STC*
Details
Tests
PDF
Wood
10mm
Yes
No
51
54
Hambro D500 composite floor system
NGC 7006005, 5006005
Finish
Underlayment(s)
Ceiling
Gypsum
ΔIIC
STC*
Details
Tests
PDF
Tile
2mm
Yes
No
51
56
22 Gauge Epic Metal's Epicore MSR floor pan
NGC 7009063, 5009041
Finish
Underlayment(s)
Ceiling
Gypsum
ΔIIC
STC*
Details
Tests
PDF
LVT
2mm
No
No
50
54
ATI C8707 02-113-11-R1
LVT
5mm
No
No
52
54
ATI C8707 03-113-11-R1
LVT
10mm*
No
No
55
54
ATI C8707 04-113-11-R1
Bamboo
5mm
No
No
51
NGC 7012005

* Neither LVT nor tile over 10mm ECOsilence are considered recommended systems, but this test report is provided as an indication of acoustic performance.

Finish
Underlayment(s)
Ceiling
Gypsum
ΔIIC
STC*
Details
Tests
PDF
LVT
2mm
No
No
52
57
ATI C6377.01-113-11
Bamboo
2mm
No
No
54
55
ATI C5673.02-113-11
Bamboo
5mm
No
No
54
55
ATI C5673.02-113-11
Laminate
2mm
No
No
58
56
ATI C5673.01-113-11
Laminate
5mm
No
No
58
55
ATI C5673.02-113-11
Finish
Underlayment(s)
Ceiling
Gypsum
ΔIIC
STC*
Details
Tests
PDF
Tile
5mm
No
No
50
NGC 7006028
Tile
5mm
Yes
No
57
62
NGC 7006099, 5006067
Bamboo
2mm
No
No
53
NGC 7012004
Wood
2mm
No
No
54
53
NGC 7005072, 5005033
Wood
2mm
Yes
No
72
72
NGC 7004004, 5004001

Assemblies

The wood frame assembly used in flooring tests were composed of five components.
Wood Frame Assembly
  1. Floor Finish
  2. Approved Adhesive
  3. ECOsilence Underlayment
  4. Approved Adhesive
  5. Gypsum Concrete
  6. Underlayment
  7. Subfloor
  8. Wood Framing
  9. Insulation
  10. Resilient Channel
  11. Suspended Ceiling
The concrete slabs used in flooring tests were composed of five components.
Concrete Slab
  1. Floor Finish
  2. Approved Adhesive
  3. ECOsilence Underlayment
  4. Approved Adhesive
  5. Concrete Slab